Podrobnosti návrhu

Číslo:prEN 17414-2
Zdroj:CEN
Komise:CEN/TC 107
Název komise:Pre-fabricated district heating pipe systems
Návrh uveřejněn:23.07.2019
K připomínkám do:10.09.2019
Contact email:cermak(at)agentura-cas.cz
Anotace:

This document specifies requirements and test methods for factory made thermally insulated bonded flexible pipe-in-pipe assemblies for directly buried district cooling distribution systems, comprising a service pipe from DN 15 to DN 200 and a casing of polyethylene. The pipe assembly may also include the following additional elements: measuring wires, spacers and diffusion barriers.

This document is intended to be used in conjunction with prEN 17414-1.

This document applies only to insulated pipe assemblies, for continuous operation with water at various temperatures (1 to 30) °C and a maximum operation pressure of 25 bar dependent on material specified.

The design is based on an expected service life with continuous operation of a minimum 50 years.

This document does not cover surveillance systems.

NOTE          For the transport of other liquids, for example potable water, additional requirements may be applicable.

Tento dokument můžete připomínkovat po jednotlivých částech  - stačí u příslušné části dokumentu vyplnit formulář v souladu s pokyny a kliknout na ‚Odeslat připomínku‘.

Prosíme, nepoužívejte vulgární výrazy a nevyužívejte tento prostor pro umisťování reklamy.