Anotace:

This generic EMC emission standard is applicable only if no relevant dedicated product or product family EMC emission standard has been published.

This part of IEC 61000 for emission requirements applies to electrical and electronic equipment intended for use at residential (see 3.1.14) locations. This part of IEC 61000 also applies to electrical and electronic equipment intended for use at other locations that do not fall within the scope of IEC 61000-6-8 or IEC 61000-6-4.

The intention is that all equipment used in the residential, commercial and light-industrial environments shall be covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt the requirements in IEC 61000-6-3 shall be applied.

The conducted and radiated emission requirements in the frequency range up to 400 GHz are considered essential and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this standard. No measurement needs to be performed at frequencies where no requirement is specified.

The emission requirements in this standard are not intended to be applicable to the intentional transmissions and their harmonics from a radio transmitter as defined by the ITU.

NOTE 1 Safety considerations are not covered by this standard.

NOTE 2 In special cases, situations will arise where the levels specified in this standard will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an equipment. In these instances, special mitigation measures may have to be employed.

NOTE 3 Disturbances generated in fault conditions of equipment are not covered by this standard.

NOTE 4 As the requirements in this standard are more stringent or equivalent to those requirements in IEC 61000-6-4 and IEC 61000-6-8, equipment fulfilling the requirements of this standard comply with the requirements of IEC 61000-6-4 and IEC 61000-6-8.

Tento dokument můžete připomínkovat po jednotlivých částech  - stačí u příslušné části dokumentu vyplnit formulář v souladu s pokyny a kliknout na ‚Odeslat připomínku‘.