Dveře a okna

Oblast zaměření: Dveře a okna
Komise : CEN/TC 33 (Doors, windows, shutters, building hardware and curtain walling)
Původce: CEN
K připomínkám do: 20.05.2019
Zobraz více Zobraz méně
 

This document specifies requirements and test/assessment/calculation methods for power operated pedestrian doorsets, other than swing type, initially designed for installation with power operation.

Such doorset constructions can be operated electro-mechanically, electro-hydraulically or pneumatically.

These doorsets include power operated pedestrian sliding doorsets, revolving doorsets, balanced (sliding/swing) doorsets and folding doorsets with one or more horizontally moving leaves.

This document applies to power operated pedestrian doorsets with flush or panelled leaves, complete with:

—    integral fanlights, if any;

NOTE A fanlight is a panel over a door, which is part of the doorset.

—    side panels that are contained within a single frame for inclusion in a single aperture, if any.

The intended uses of the products covered by this document are:

—    doorsets with or without fire resistance and smoke control characteristics for external use in escape routes and other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy and tightness in construction works;

—    doorsets with or without fire resistance and smoke control characteristics for internal use in escape routes, communication and other declared specific uses and/or uses subject to other specific requirements, in particular noise in construction works;

—    doorsets with or without fire resistance and smoke control characteristics for internal use in escape routes, communication and other declared specific uses and/or uses subject to other specific requirements, in particular noise and energy in construction works.

The products covered by this document are not assessed for structural applications of the building.

This document does not cover operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000‑6‑2.

This document does not apply to:

—    external pedestrian doorsets according to EN 14351‑1;

—    internal pedestrian doorsets according to EN 14351‑2;

—    lifts doorsets;

—    vehicles doorsets;

—    doorsets used in industrial processes;

—    doorsets in partition walls;

—    doorsets outside the reach of people (such as crane gantry fences);

—    pedestrian entrance control equipment such as turnstiles, swing lanes and retractable lanes;

—    platform doorsets.

This document does not cover special functions of doorsets (e.g. security).

Oblast zaměření: Dveře a okna
Komise : CEN/TC 33 (Doors, windows, shutters, building hardware and curtain walling)
Původce: CEN
K připomínkám do: 27.05.2019
Zobraz více Zobraz méně
 

This document specifies requirements for performance and testing of Mechatronic Cylinders and their keys and/or electronic keys.

It applies to cylinders for such locks designed to be normally used in buildings. It also applies to cylinders for use with other hardware products such as exit devices, door operators, etc. or monitoring facilities and alarm systems.

It establishes categories of use based on performance tests and grades of security based on design requirements and on performance tests that simulate attack.

This document includes assessment of additional features when they are included in the cylinder design.

This document does not cover any other element of a security system, other than those directly involved in the control of a cylinder.

The suitability of cylinders for use on fire or smoke-door assemblies is determined by fire performance tests conducted in addition to the performance testing specified by this document (see Annex A).

Oblast zaměření: Dveře a okna
Komise : CEN/TC 33 (Doors, windows, shutters, building hardware and curtain walling)
Původce: CEN
K připomínkám do: 27.05.2019
Zobraz více Zobraz méně
 

This document applies to power-operated pedestrian swing door drives with self closing function using mechanically stored energy for single and double leaf swing doors with fire resistance and smoke control characteristics.

This document does not apply to:

—    Electrically controlled hold-open systems according to EN 14637;

—    Door coordinating devices according to EN 1158;

—    Electrically powered hold-open devices for swing doors according to EN 1155.

If a power-operated pedestrian swing door drive with self closing function is part of a door coordinator device for double leaf swing doors, the complete system will comply with EN 1158.

If a power-operated pedestrian swing door drive with self-closing function is part of an electrically controlled hold-open system, the complete system will comply with EN 14637.