Odvodňovací zařízení

Oblast zaměření: Odvodňovací zařízení
Komise : CEN/TC 165 (Wastewater engineering)
Původce: CEN
K připomínkám do: 17.12.2018
Zobraz více Zobraz méně
 

This document specifies characteristics and related requirements, assessment methods, the marking and assessment and verification of constancy of performance (AVCP) procedures for prefabricated secondary treatment units for populations up to 50 inhabitants.

Prefabricated secondary treatment units in accordance with this document are:

•      used for the treatment of effluent from product in accordance with EN 12566‑1;

Equivalent septic effluent may come from existing septic tanks.

•      made of concrete, steel, Unplasticized Polyvinylchloride (PVC-U), Polyethylene (PE), Polypropylene (PP), Glass Reinforced Polyester (GRP-UP), Polydicyclopentadiene (PDCPD), PVC and/or EPDM;

•      used buried in the ground;

•      with or without extension shaft;

•      made of prefabricated components that are factory or site-assembled by one manufacturer and which are tested as a whole.

This document does not cover prefabricated secondary treatment units:

•      where vehicle loads apply to it;

•      with direct infiltration into the ground (non-watertight);

•      made of retrofit kits (see definition in 3.1.5).

The assessment methods specified in this European Standard establish the performance of the prefabricated secondary treatment unit, needed to verify its suitability for the condition in which it is normally installed.

Oblast zaměření: Odvodňovací zařízení
Komise : CEN/TC 165 (Wastewater engineering)
Původce: CEN
K připomínkám do: 17.12.2018
Zobraz více Zobraz méně
 

This document specifies characteristics and related requirements, assessment methods, the marking and assessment and verification of constancy of performance (AVCP) procedures for packaged and/or site assembled domestic wastewater treatment plants used for populations up to 50 inhabitants.

Packaged and/or site assembled domestic wastewater treatment plants in accordance with this document are:

•      used for the treatment of domestic wastewater including that of guest houses and businesses.

•      made of concrete, steel, Unplasticized Polyvinylchloride (PVC-U), Polyethylene (PE), Polypropylene (PP), Glass Reinforced Polyester (GRP-UP), Polydicyclopentadiene (PDCPD), PVC and/or EPDM;

•      used buried in the ground;

•      with or without extension shaft;

•      made of prefabricated components that are factory or site-assembled by one manufacturer and which are tested as a whole.

This document does not cover packaged and/or site assembled domestic wastewater treatment plants where vehicle loads apply to it.

The assessment methods specified in this document establish the performance of the packaged and/or site assembled domestic wastewater treatment plant, needed to verify its suitability for the condition in which it is normally installed.

Oblast zaměření: Odvodňovací zařízení
Komise : CEN/TC 165 (Wastewater engineering)
Původce: CEN
K připomínkám do: 17.12.2018
Zobraz více Zobraz méně
 

This document specifies characteristics and related requirements, assessment methods, the marking and assessment and verification of constancy of performance (AVCP) procedures for packaged and/or site assembled septic tank used for populations up to 50 inhabitants.

Packaged and/or site assembled septic tanks in accordance with this document are:

•      used for the primary treatment of domestic wastewater including that of guest houses and businesses;

•      made of concrete, steel, Unplasticized Polyvinylchloride (PVC-U), Polyethylene (PE), Polypropylene (PP), Glass Reinforced Polyester (GRP-UP) and/or Polydicyclopentadiene (PDCPD);

•      with or without elastomeric seals for joints made of vulcanized rubber;

•      used buried in the ground;

•      with or without extension shaft;

•      with a nominally capacity of at least 2 m3;

•      made of prefabricated components that are factory or site-assembled by one manufacturer and which are tested as a whole.

This document does not cover packaged and/or site assembled septic tank:

•      where vehicle loads apply to it;

•      receiving grey water only.

Oblast zaměření: Odvodňovací zařízení
Komise : CEN/TC 165 (Wastewater engineering)
Původce: CEN
K připomínkám do: 17.12.2018
Zobraz více Zobraz méně
 

This document specifies characteristics and related requirements, assessment methods, the marking and assessment and verification of constancy of performance (AVCP) procedures for prefabricated tertiary treatment units used for populations up to 50 inhabitants.

Prefabricated tertiary treatment units in accordance with this document are:

•      used for the tertiary treatment of domestic wastewater coming from:

a) products in accordance with EN 12566‑3 or EN 12566‑6 or;

b) installation designed and constructed in accordance with CEN/TR 12566‑5.

Equivalent secondary treated effluent may come from existing systems.

•      made of concrete, steel, Unplasticized Polyvinylchloride (PVC-U), Polyethylene (PE), Polypropylene (PP), Glass Reinforced Polyester (GRP-UP), Polydicyclopentadiene (PDCPD), PVC and/or EPDM.

•      used buried in the ground;

•      with or without extension shaft;

•      made of prefabricated components that are factory or site-assembled by one manufacturer and which are tested as a whole.

This document does not cover prefabricated tertiary treatment units:

•      where vehicle loads apply to it;

•      with direct infiltration into the ground (non-watertight);

•      made of retrofit kits (see definition in 3.1.9);

•      forming part of products covered by EN 12566‑3 and EN 12566‑6;

•      for microorganism reduction.

The assessment methods specified in this document establish the performance of the prefabricated tertiary treatment unit, needed to verify its suitability for the condition in which it is normally installed.