Vodiče pro vinutí

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 2.07.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies general requirements of glass-fibre wound, resin or varnish impregnated, bare or enamelled rectangular copper wire.

The range of nominal conductor dimensions is given in subclause 4.1 and the relevant specification sheet.

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 2.07.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies the general requirements of enamelled rectangular copper winding wires.

The range of nominal conductor dimensions is given in 4.1 and the relevant specification sheet.

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 9.07.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding wire of class 200 with a sole coating based on polyesterimide resin, which may be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements.

NOTE   A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.

The range of nominal conductor dimensions covered by this standard is:

–    width:             min. 2,0 mm        max. 16,0 mm;

–    thickness:       min. 0,80 mm       max. 5,60 mm.

Wires  of  grade  1  and  grade  2  are  included  in  this  specification  and  apply  to  the  complete range of conductors.

The  specified  combinations  of  width  and  thickness  as  well  as  the  specified  width/thickness ratio are given in IEC 60317-0-2:2019.

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 9.07.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies requirements of polyester glass-fibre wound resin/varnish impregnated bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based.

The nominal conductor diameters are specified in clause 4 of IEC 60317-0-10:2017.

NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: CEN
K připomínkám do: 9.07.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies requirements of polyester glass-fibre wound unvarnished and fused bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 155.

The nominal conductor diameters are specified in clause 4 of IEC 60317-0-10:2017.

NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 9.07.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies requirements of polyester glass-fibre wound, silicone resin or varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding wire, temperature index 200. The impregnating agent is a silicone containing resin or varnish.

The range of nominal conductor dimensions covered by this standard is:

–        width:          min.    2,0     mm     max.   16,0    mm;
–        thickness:     min.    0,80    mm     max.     5,60  mm.

The specified combinations of width and thickness as well as the specified width/thickness ratio are according to IEC 60317-0-8.

NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 9.07.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies requirements of polyester glass-fibre wound, resin or varnish impregnated or not impregnated, bare or grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based.

The range of nominal conductor dimensions covered by this standard is:

< >< >

NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 9.07.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies requirements of polyester glass-fibre wound fused, unvarnished, bare or grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 155.

NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

The range of nominal conductor dimensions covered by this standard is:

< >< >

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 9.07.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies the requirements of enamelled round aluminium winding wire of class 200 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide-imide resin.

NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.

The range of nominal conductor diameters covered by this standard is:

–   Grade 1: 0,400 mm up to and including 3,150 mm;

–   Grade 2: 0,400 mm up to and including 5,000 mm.

The nominal conductor diameters are specified in clause 4 of IEC 60317-0-3:2008.

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 9.07.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding wire of class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements

NOTE1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.

NOTE2 Polyvinyl acetal is a general name for a family of thermoplastic vinyl resins produced by the condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl butyral.

The range of nominal conductor dimensions covered by this standard is:

–   width:      min.     2,0   mm     max.   16,0    mm;

–   thickness: min.     0,80  mm     max.     5,60  mm.

Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors.

The specified combinations of width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2:2019.

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 9.07.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding wire of class 105 with a sole coating based on polyvinyl acetal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements

NOTE1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.

NOTE2 Polyvinyl acetal is a general name for a family of thermoplastic vinyl resins produced by the condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl butyral.

The range of nominal conductor dimensions covered by this standard is:

–   width:      min.     2,0   mm     max.   16,0    mm;

–   thickness: min.     0,80  mm     max.     5,60  mm.

Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors.

The specified combinations of width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2:2019.

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 9.07.2019
Zobraz více Zobraz méně
 

This Part of IEC 60317 specifies the requirements of enamelled round copper winding wire of class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements.

NOTE1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.

NOTE2 Polyvinyl acetal is a general name for a family of thermoplastic vinyl resins produced by the condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl butyral.

The range of nominal conductor diameters covered by this standard is:

–   Grade 1: 0,040 mm up to and including 2,500 mm;

–   Grade 2: 0,040 mm up to and including 5,000 mm;

–   Grade 3: 0,080 mm up to and including 5,000 mm.

The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 23.07.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies requirements of polyester glass-fibre wound, resin or varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding wire, temperature index 180. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based.

NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

The range of nominal conductor dimensions covered by this standard is:

< >

The specified combinations of width and thickness as well as the specified width/thickness ratio are according to IEC 60317-0-8.

Oblast zaměření: Vodiče pro vinutí
Komise : IEC/TC 55 (Winding wires)
Původce: ISO\IEC\CEN\CENELEC
K připomínkám do: 6.08.2019
Zobraz více Zobraz méně
 

This part of IEC 60317 specifies general requirements of glass-fibre wound resin or varnish impregnated, bare or enamelled, round copper winding wires.

The range of nominal conductor diameters is given in the relevant specification sheet.

When a reference is made to a winding wire according to one of the IEC 60317 series, the following information should be given in the description:

–   reference to IEC specification;

–   nominal conductor diameter in millimetres;

–   grade of coating and glass covering.

The coating shall be characterised by the following different grades of thickness:

–   GL1, bare conductor with 1 layer of glass fibre

–    GL2, bare conductor with 2 layers of glass fibre

–    grade 1 GL1, enamelled grade 1 (grade 1) with 1 layer of glass fibre (GL1)

–    grade 1 GL2, enamelled grade 1 (grade 1) with 2 layers of glass fibre (GL2)

–    grade 2 GL1, enamelled grade 2 (grade 2) with 1 layer of glass fibre (GL1)

–   grade 2 GL2, enamelled grade 2 (grade 2) with 2 layers of glass fibre (GL2)